►Based on self
-copyright IC
►Provide 2
impedances: 75 Ohm unbalance and 120 Ohm balance;
►V.35 interface supports hot-plug, supports DTE or DCE device interconnection
►Provide 3 clock types: Internal clock, External clock,E1 line clock;Overview
This interface converter provides one E1 interface and one V.35 interface to achieve framed E1 interface transferring to V.35 interface. The data channel rate is 2.048Mbps. The device has inter-set loop test function to facilitate the project launching and daily maintenance.
Features
►Based on self -copyright ICApplication
Technical Indexes
Parameter |
Specification |
E1 Interface |
|
Interface Standard |
comply with protocol G.703 |
Interface Rate |
n*64Kbps±50ppm |
Interface Code |
HDB3 |
E1 Impedance: |
75Ω (unbalance), 120Ω (balance) |
Jitter tolerance |
In accord with protocol G.742 and G.823 |
Allowed Attenuation |
0~6dBm |
V.35 Interface |
|
Interface rate |
n*64Kbps |
Interface Standard |
Compatible with V.35 Standard |
Connector |
DB25 |
Connect Mode |
DCE |
Clock Type |
G.703 restored clock, Internal clock |
Power |
|
Power supply |
AC180V ~ 260V;DC –48V;DC +24V |
Power consumption |
≤10W |
Dimension |
|
Product Size |
216X140X31mm( WXDXH)) |
Simple Packaging |
274X193 X84mm ( WXDXH) |
Piece weight |
1.25KG |
Working environment |
|
Working temperature |
-10°C ~ 50°C |
Working Humidity |
5%~95 % (no condensation) |
Storage temperature |
-40°C ~ 80°C |
|
5%~95 % (no condensation) |
Model |
Description |
LNK-E1V1 |
Unframed E1-V.35 Converter, E1 Interface 120ohm or 75ohm, V.35 Interface (DB25 Connector, DCE mode), AC220V or DC-48V |